Troubleshooting and Recovery 417
To add and configure SNMP alerts using the CMC Web interface:
1
Log in to the CMC Web interface.
2
Select
Chassis
in the system tree.
3
Click the
Alerts
tab. The
Chassis Events
page appears.
4
Enable alerting:
a
Select the check boxes of the events for which you want to enable
alerting. To enable all events for alerting, select the
Select All
check
box.
b
Click
Apply
to save your settings.
5
Click the
Traps Settings
subtab.The
Chassis Event Alert Destinations
page displays.
6
Type a valid address in an empty
Destination
field.
NOTE: A valid address is an address that receives the trap alerts. Use the
"quad-dot" IPv4 format, standard IPv6 address notation, or FQDN. For example:
123.123.123.123 or 2001:db8:85a3::8a2e:370:7334 or dell.com
7
Type t h e
SNMP Community String
to which the destination
management station belongs.
NOTE: The community string on the Chassis Event Alert Destinations page
differs from the community string on the Chassis Network Services page.
The SNMP traps community string is the community that CMC uses for
outbound traps destined to management stations. The community string on
the Chassis Network Services page is the community string that
management stations use to query the SNMP daemon on CMC.
8
Click
Apply
to save your changes.