Owner's Manual
360 Power Management
The
I/O Modules Status
page displays.
3
Click the
Power
tab.
The
Power Control
page displays.
4
Select the operation you want to execute (
reset
or
power cycle
) from the
drop-down menu beside the IOM in the list.
5
Click
Apply
.
A dialog box appears requesting confirmation.
6
Click
OK
to perform the power management action (for example,
cause the IOM to power cycle).
Using RACADM
To execute power control operations on an IOM using RACADM:
Open a serial/Telnet/SSH text console to CMC, log in, and type:
racadm chassisaction -m switch-<n> <action>
where
<
n
> is a number 1-6 and specifies the IOM (A1, A2, B1, B2, C1, C2),
and
<
action
> indicates the operation you want to execute:
powercycle
or
reset
.
Executing Power Control Operations on a Server
NOTE: To perform power management actions, you must have Chassis
Configuration Administrator privilege.
CMC enables you to remotely perform several power management actions, for
example, an orderly shutdown, on an individual server in the chassis.
Using the Web Interface
To execute power control operations on a server using the Web interface:
1
Log in to the CMC Web interface.
2
Expand
Server Overview
in the system tree, and then select the server on
which you want to execute a power control operation. The
Server Status
page displays.
3
Click the
Power
tab.
The
Server Power Management
page displays.