Owner's Manual

Using the CMC Web Interface 205
Viewing the Current Firmware Versions
The Update page displays the current version of all the updatable
components in the chassis. These may include the iKVM firmware, active
CMC firmware, (if applicable) the standby CMC firmware, the iDRAC
firmware, and the IOM infrastructure device firmware. For more information,
see "Updating the IOM Infrastructure Device Firmware" on page 209.
To view the chassis components that can be updated:
1
Log in to the Web interface. For more information, see "Accessing the
CMC Web Interface" on page 109.
2
Click
Chassis Overview
in the system tree.
NOTE: Alternatively, click Chassis Controller in the system tree.
3
Click the
Update
tab. The
Firmware Update
page appears.
To view the updatable server components:
1
Log in to the Web interface. For more information, see "Accessing the
CMC Web Interface" on page 109.
2
Click
Server Overview
in the system tree.
3
Click the
Update
tab. The
Server Component Update
appears.
To open an update page for selected devices:
1
Click on the device name or select the
Select/Deselect All
option.
2
Click
Apply
Update.
An update page for the selected devices displays.
If the chassis contains an earlier generation server whose iDRAC is in recovery
mode or if CMC detects that iDRAC has corrupted firmware, then the earlier
generation iDRAC is also listed on the Firmware Update page. For the steps
to recover iDRAC firmware using CMC, see "Recovering iDRAC Firmware
Using CMC" on page 211.