Users Guide

Table Of Contents
Enabling or Disabling Warning Message to Change Default
Login Password Using RACADM
To enable the display of the warning message to change the default login password using RACADM, use racadm config -g
cfgRacTuning -o cfgRacTuneDefCredentialWarningEnable<0> or <1> object. For more information, see the Chassis
Management Controller for PowerEdge VRTX RACADM Command Line Reference Guide available at dell.com/support/manuals.
Forcing password change using web interface
You can change the default password when you are accessing the CMC interface for the first time. The feature is applicable in
environments that are network accessible and require authentication of username and password. You can configure and reset the Forced
Password Change feature anytime. It is mandatory to change your password to log in and access the CMC web interface. The username
is "root", by default.
1. Enter the New Password.
The maximum characters for the password are 20. The characters are masked. The following characters are supported:
0-9
A-Z
a-z
Special characters: +, &, ?, >, -, }, |, ., !, (, ', ,, _, [, ", @, #, ), *, ;, $, ], /, §, %, =, <, :, {, I, ~, and \
CMC does not support extended ASCII characters, such as ß, å, é, ü, or other characters used primarily in non-English languages.
Setting values with these characters causes unpredictable behavior.
2. Reenter the new password in the Confirm Password text box.
3. Click Continue to submit the new password for logging into the CMC web interface.
Use case scenarios
This section describes typical use cases and tasks that you can perform with Chassis Management Controller Version 3.3 for Dell
PowerEdge VRTX.
Conversion of External Shared PERC 8 card High
Availability to Non-High Availability Mode using Web
Interface
Dell PowerEdge VRTX chassis must have 2 External Shared PERC 8 cards in PCI slot 5 and PCI slot 6 in HA mode.
Workflow
1. Power down chassis. Disconnect all SAS cables from External Shared PERC 8 cards to MD12x0 enclosures.
2. Power Up chassis.
3. Login to CMC web interface and navigate to the Storage→ Controllers→ Troubleshooting and disable Fault tolerance from the
drop-down menu for External Shared PERC 8 card in slot 5, click Apply and select disable for slot 6, and then click Apply.
4. Resetting both the PERCs may take two minutes to reflect in Non-HA mode.
5. Power down chassis and connect the enclosures in Non-HA Mode.
6. Power Up chassis.
7. External Shared PERC 8 card is not in HighAvailabiltiy Mode and navigate to Storage→ Troubleshooting→ Setup Troubleshooting
to view the Non-HA status.
Conversion of External Shared PERC 8 card Non-High
Availability to High Availability Mode using Web Interface
Dell PowerEdge VRTX chassis must have 2 External Shared PERC 8 cards in PCI slot 5 and PCI slot 6.
Workflow
Logging in to CMC
45