Users Guide

Table Of Contents
Configuring LED Blinking Using RACADM
Open a serial/Telnet/SSH text console to CMC, log in, and type:
racadm setled -m <module> [-l <ledState>], where <module> specifies the module whose LED you want to configure.
Configuration options:
server-n where n = 1-4
switch-1
cmc-active
and <ledState> specifies whether or not the LED should blink. Configuration options:
0 — not blinking (default)
1 — blinking
racadm raid <operation> <component FQDD>, where the operation value is blink or unblink, and the FQDD is for the
component's physical disk drive, virtual disk and enclosures.
Configuring CMC Properties
You can configure CMC properties such as power budgeting, network settings, users, and SNMP and email alerts using the web interface
or RACADM commands.
Configuring iDRAC Launch Method Using CMC
Web Interface
To configure the iDRAC launch method from the General Chassis Settings page:
1. In the left pane, click Chassis Overview > Setup.
The General Chassis Settings page is displayed.
2. In the drop-down menu for the iDRAC Launch Method property, select IP Address or DNS.
3. Click Apply.
NOTE:
A DNS-based launch is used for any particular iDRAC only if:
The chassis setting is DNS.
CMC has detected that the specific iDRAC is configured with a DNS name.
Configuring iDRAC Launch Method Using
RACADM
To update CMC firmware using RACADM, use the cfgRacTuneIdracDNSLaunchEnable subcommand. For more information, see
the Chassis Management Controller for PowerEdge VRTX RACADM Command Line Reference Guide available at dell.com/support/
manuals.
Configuring Login Lockout Policy Attributes Using
CMC Web Interface
NOTE: To perform the following tasks, you must have Chassis Configuration Administrator privilege.
The Log in Security enables you to configure the IP range attributes for CMC login using the CMC web interface. To configure the IP
range attributes using CMC web interface:
1. In the left pane, go to Chassis Overview and click Network > Network.
The Network Configuration page is displayed.
Installing and Setting Up CMC
35