Release Notes

Known Issues
Topics:
Flex address disabled after racresetcfg of CMC
RAID-related operations might take longer to report status
Error occurs while importing CMC configuration file
Chassis overview health tab does not display alert
Server components update page gets corrupt
Controller failover feature does not work
Active alert for degraded virtual disk is not displayed
SPERC information is displayed partially on LCD display
Unable to view chassis logs from remote RACADM
Static IPv6 IP address can be assigned to iDRAC blades
Flex address disabled after racresetcfg of CMC
Description XWKGY_Intel10G card shows Flex address disabled after racresetcfg of CMC in Network Device page and
OS.
Resolution Virtual reseat or physical reseat of the server
Versions/Systems
affected
All CMC versions including CMC 3.20 for Dell PowerEdge VRTX and PowerEdge servers with iDRAC7 or earlier.
RAID-related operations might take longer to
report status
Description
After Shared PERC8 controller update, RAID-related operations may take longer to report status.
Resolution Wait for the operation status to report.
Versions/Systems
affected
CMC version 2.01 or later for Dell PowerEdge VRTX.
Error occurs while importing CMC configuration
file
Description
An error occurs while importing CMC configuration file using local or remote RACADM.
Resolution This issue occurs when IPv6 is enabled or disabled from the configuration file. Enable or disable IPv6 using the
command, racadm config -g cfgIPv6LanNetworking -o cfgIPv6Enable 0.
Versions/Systems
affected
CMC Version 2.0 or later for Dell PowerEdge VRTX
Chassis overview health tab does not display alert
Description
At times when foreign drives are inserted, the Chassis Overview Health tab does not display the alert, “Foreign
Configuration was detected on Physical Disk”.
8
14 Known Issues