CLI Guide
Table 96. Details of get tempprobes (continued)
MaximumWarningThreshold = 65 C
MinimumFailureThreshold = -2 C
MaximumFailureThreshold = 65 C
TempSensor.Embedded.1:Enclosure.External.0-0:RAID.ChassisSlot.5-1
Status = Ok
State = Ready
Name = Temp Sensor 1
ReadingDegreeCelcius = 31 C
MinimumWarningThreshold = -2 C
MaximumWarningThreshold = 65 C
MinimumFailureThreshold = -2 C
MaximumFailureThreshold = 65 C
TempSensor.Embedded.2:Enclosure.External.0-0:RAID.ChassisSlot.5-1
Status = Ok
State = Ready
Name = Temp Sensor 2
ReadingDegreeCelcius = 27 C
MinimumWarningThreshold = 12 C
MaximumWarningThreshold = 50 C
MinimumFailureThreshold = 3 C
MaximumFailureThreshold = 55 C
TempSensor.Embedded.3:Enclosure.External.0-0:RAID.ChassisSlot.5-1
Status = Ok
State = Ready
Name = Temp Sensor 3
ReadingDegreeCelcius = 26 C
MinimumWarningThreshold = 13 C
MaximumWarningThreshold = 46 C
MinimumFailureThreshold = 3 C
MaximumFailureThreshold = 55 C
hotspare
Table 97. Details of hotspare
Description
Assign or unassign global and dedicated hotspares.
Synopsis
racadm raid hotspare:<PD FQDD> -assign {yes | no} {type {ghs | dhs}} {-
vdkey:<VD FQDD>} {-current | -pending}
Input
• –current <optional>: Performs the configuration right now.
NOTE: If this requires the system to reboot it will reboot then.
• –pending: Save the configuration change for a later application. You can use a combination of the –pending
and –current flags on multiple commands to reduce the possible number of system reboots.
• –assign {yes | no}: Assign or Unassign the physical disk drive as a hotspare.
• –type { ghs | dhs} : Assign as a global or dedicated hotspare.
• –vdkey: <VD FQDD>: Required for dedicated hotspare. Assign the dedicated hotspare to the specified VD.
Example
racadm raid
hotspare:Disk.Bay.0:Enclosure.Internal.0-0:RAID.ChassisIntegrated.1-1 -
assign no
racadm raid
hotspare:Disk.Bay.0:Enclosure.Internal.0-0:RAID.ChassisIntegrated.1-1 -
assign yes -type ghs
racadm raid
hotspare:Disk.Bay.0:Enclosure.Internal.0-0:RAID.ChassisIntegrated.1-1 -
assign yes -type dhs -vdkey:Disk.Virtual.0:RAID.ChassisIntegrated.1-1
90 RACADM Subcommand Details