CLI Guide

Table 94. Details of get fans (continued)
Speed = 4670 RPMS
Fan.Slot.1:Enclosure.External.0-0:RAID.ChassisSlot.5-1
FanOperationalStatus = Ok
State = Ready
Name = Fan 1
Speed = 4670 RPMS
Fan.Slot.2:Enclosure.External.0-0:RAID.ChassisSlot.5-1
FanOperationalStatus = Ok
State = Ready
Name = Fan 2
Speed = 4670 RPMS
Fan.Slot.3:Enclosure.External.0-0:RAID.ChassisSlot.5-1
FanOperationalStatus = Ok
State = Ready
Name = Fan 3
Speed = 4700 RPMS
get psus
Table 95. Details of get psus
Description Displays the status and attributes of the Power Supply Unit (PSU) in the storage enclosure that are
connected to chassis
NOTE: To use this subcommand, you must have the CMC Login User privilege.
Synopsis
racadm raid get psus -o -p Status
racadm raid get psus -o
Input -o — The -o is used to display the fault-tolerant status of a enclosure.
Example
racadm raid get psus -o -p Status
PSU.Slot.0:Enclosure.External.0-1:RAID.ChassisSlot.5-1
Status = Ok
PSU.Slot.1:Enclosure.External.0-1:RAID.ChassisSlot.5-1
Status = Ok
PSU.Slot.0:Enclosure.External.0-0:RAID.ChassisSlot.5-1
Status = Ok
PSU.Slot.1:Enclosure.External.0-0:RAID.ChassisSlot.5-1
Status = Ok
racadm raid get psus -o
PSU.Slot.0:Enclosure.External.0-1:RAID.ChassisSlot.5-1
Status = Ok
State = Ready
Name = PSU 0
PartNumber = 0NFCG1A01
PSU.Slot.1:Enclosure.External.0-1:RAID.ChassisSlot.5-1
Status = Ok
State = Ready
Name = PSU 1
PartNumber = 0NFCG1A01
PSU.Slot.0:Enclosure.External.0-0:RAID.ChassisSlot.5-1
Status = Ok
State = Ready
Name = PSU 0
PartNumber = 0D1YWRA00
PSU.Slot.1:Enclosure.External.0-0:RAID.ChassisSlot.5-1
88
RACADM Subcommand Details