CLI Guide
• <Presence>
• <NIC1 MAC Address>
• <NIC2 MAC Address>
getmodinfo
Table 48. getmodinfo
Description
Displays configuration and status information for all modules or a specified module (server, switch, CMC, fan unit,
blower, power supply unit, chassis, DVD, main-board, IO cable, and FPC cable) in the chassis.
To use this subcommand, you must have CMC Login User privilege.
NOTE: The service tag field is blank for modules that do not have service tags.
Synopsis
racadm getmodinfo [-m <module>] [-A]
Input
• -m <module> — Specifies the module for which the configuration and status information is required. The
default command (no options) displays information about all the major components in the chassis.
<module> can be one of the following values:
○ server-n, where n = 1 to 4
○ switch-n, where n = 1
○ CMC-n, where n = 1 or 2
○ fan-n, where n = 1 to 6
○ blower-n, where n = 1 to 4
○ ps-n, where n = 1 to 4
○ chassis
○ dvd
○ main-board
○ io-cable
○ fpc-cable
○ storage
• -A — Does not display the headers and labels in the output.
Example
• racadm getmodinfo -m switch-1
<module> <presence> <pwrState> <health>
<svcTag> <nodeId>
Switch-1 Present
ON OK N/
A N/A
• racadm getmodinfo
NOTE: A power state of "Primary" denotes Active CMC.
<module> <presence> <pwrState> <health> <svcTag>
<nodeId>
Chassis Present ON
Not OK 3BPV622 N/A
Main-Board Present ON
OK N/A N/A
Storage Present
ON OK 3BPV622
Fan-1 Unknown N/A
Not OK N/A N/A
Fan-2 Present ON
OK N/A N/A
Fan-3 Present ON
RACADM Subcommand Details 51