Users Guide

One Shared PERC detected
One expanders detected
Shared PERC and expanders correctly cabled
View the status of each attribute that indicates if the fault-tolerant criteria is fulfilled.
NOTE: If the attribute in a fault-tolerant environment is not matching the criterion, then an Update Now option is
displayed for that attribute.
NOTE: A Learn How option is displayed against some of the attributes. For more information about the attribute,
click Learn How.
3. To fulfill a criterion for an attribute, click Update Now.
The Storage Component Update page is displayed, which allows you to update the required storage component to fulfill the
criterion for the attribute.
Assigning Virtual Adapters To Slots Using CMC
Web Interface
Using the Virtual Adapter feature, you can share the installed storage with the four servers. You can map a virtual disk to a server slot by
first mapping a virtual disk to a virtual adapter (VA), and then mapping a Virtual Adapter (VA) to a server slot.
Before assigning a VA to a server slot, ensure that:
The server slot is empty, or the server in the slot is turned off.
The VA is unmapped from a server or a slot.
All affected servers are powered off.
Virtual disks are created and they are assigned as Virtual Adapter 1, Virtual Adapter 2, Virtual Adapter 3, or Virtual Adapter 4.
For more information, see Applying Virtual Adapter Access Policy to Virtual Disks.
NOTE:
You can map only one virtual adapter to one server at a time.
Without an appropriate license, you can unmap a VA–server assignment, or map the VA to the default serve, only.
The default mapping is VA1–Server Slot 1, VA2–Server Slot 2, VA3–Server Slot 3, and VA4–Server Slot 4.
If full height server is inserted, then the upper slot has the VA mapped to it while the bottom slot is still unmapped.
For example, a full height in slot 1 has VA1 assigned to slot 1 and VA3 is still unmapped.
If the system has an enterprise license, then you can assign any one of the four VAs to a server slot. However, you
can still map one virtual adapter to one server at a time.
Virtual adapter rules are applied to the external and integrated shared storage adapters.
To map or unmap a virtual adapter from a server slot:
1. In the left pane, click Chassis Overview > Storage > Setup > Virtualization.
The Storage Virtualization page is displayed.
2. To select the required type of assignment, from the Assignment Mode: Virtual Disks to Virtual Adapters table, select:
Single Assignment — Select to assign one virtual disk to one virtual adapter.
Multiple Assignment — Select to assign a virtual disk to multiple virtual adapters. Read the on-screen instructions before
selecting this option.
NOTE:
Select the Multiple Assignment mode only when the servers have Cluster Services installed on them. Use of
this mode without Cluster Services may lead to corrupted or lost data.
NOTE: You can assign a virtual disk to multiple virtual adapters from CMC CLI even when the Assignment Mode is
set to Single Assignment in the CMC web interface.
3. In the Virtual Adapters Mapped table, from the Action drop-down list, select one of the following options, and then click Apply.
<Slot #> — Select the slot to which the VA must be assigned.
Unmap — Select to remove the VA assignment to a slot.
The VA is mapped or unmapped from the selected server slot, based on the selected action.
170
Managing Chassis Storage