Release Notes
Versions/Systems
affected
CMC Version 1.36 or earlier for Dell PowerEdge VRTX
Controller failover feature does not work
Description When pinned cache is present, the controller failover feature does not work.
Resolution Address the pinned cache before controller failover is enabled.
Versions/Systems
affected
All CMC versions including CMC 3.00 for Dell PowerEdge VRTX
Active alert for degraded virtual disk is not
displayed
Description If SPERC controller failover is triggered when the virtual disk (VD) re-build operation is in progress, an active alert
for the degraded VD is not displayed on the Chassis Overview page.
Resolution None
An active alert along with the CMC log is generated for degraded VD (VDR8) before the SPERC controller
failover is triggered. After the SPERC controller failover occurs, the active alert message for degraded VD on the
Chassis Overview page is cleared, but SPERC functionality is not impacted.
Versions/Systems
affected
All CMC versions including CMC 3.00 for Dell PowerEdge VRTX
SPERC information is displayed partially on LCD
display
Description
SPERC information is displayed partially on LCD display.
Resolution None
SPERC information can be queried using other user interfaces, only partial information is shown on LCD. The
functionality for SPERC is not affected.
Versions/Systems
affected
CMC Version 3.0 or later for Dell PowerEdge VRTX
Unable to view chassis logs from remote RACADM
Description
Unable to view chassis logs from remote RACADM
Resolution None
Use firmware RACADM instead, to view the chassis logs.
Versions/Systems
affected
All CMC versions 3.20 for Dell PowerEdge VRTX using OM 911 and later.
Tracking number 109003
Known Issues 15