CLI Guide

racadm raid changepolicy:Disk.Virtual.0:RAID.ChassisIntegrated.1-1 -wp
{wt|wb} -rp {nra|ra|ara} -dcp {enabled|disabled|default} racadm raid
rename:Disk.Virtual.0:RAID.ChassisIntegrated.1-1 -name <VD name>
racadm raid rename:Disk.Virtual.0:RAID.ChassisIntegrated.1-1 -name <VD
name>
racadm raid ctrlprop:RAID.ChassisIntegrated.1-1 [-rebuild <value>>] [-
bgi <value>] [-reconstruct <value>] [-checkconsistency <value>] [-ccmode
{abortonerror | normal}] [-copybackmode {off | on | onwithsmart}] [-lb
{auto | disabled}] [-prunconfigured {yes | no}]
racadm raid
rebuild:Disk.Bay.0:Enclosure.Internal.0-0:RAID.ChassisIntegrated.1-1
racadm raid
cancelrebuild:Disk.Bay.0:Enclosure.Internal.0-0:RAID.ChassisIntegrated.1
-1
racadm raid disableperc:RAID.ChassisIntegrated.2-1
racadm raid enableperc:RAID.ChassisIntegrated.2-1
racadm raid createsecuritykey:RAID.ChassisIntegrated.1-1 -key <Key id> -
passwd <passphrase>
racadm raid modifysecuritykey:RAID.ChassisIntegrated.1-1 -key <Key id> -
oldpasswd <oldpassphrase> -newpasswd <newpassphrase>
racadm raid deletesecuritykey:RAID.ChassisIntegrated.1-1
racadm raid encryptvd:Disk.Virtual.0:RAID.ChassisIntegrated.1-1
racadm raid
cryptographicerase:Disk.Bay.0:Enclosure.Internal.0-0:RAID.ChassisIntegra
ted.1-1
racadm raid unlock:RAID.ChassisIntegrated.1-1 -key <Key id> -passwd
<passphrase>
rebuild
Table 104. Details of rebuild
Description
Starts a rebuild on a specified virtual drive.
Synopsis
racadm raid rebuild:<PQ FQDD> {-current | -pending}
Input
–current <optional>: Performs the configuration.
NOTE: If this requires the system to restart, the system is restarted.
–pending: Save the configuration change for a later use. You can use a combination of the –pending and –
current flags on multiple commands to reduce the possible number of system restarts.
Example
racadm raid
rebuild:Disk.Bay.0:Enclosure.Internal.0-0:RAID.ChassisIntegrated.1-1
resetconfig
Table 105. Details of resetconfig
Description
Removes the current RAID Configuration (Virtual Drives and Hotspares) from the RAID controller. This operation is
not data-destructive, but is difficult to reverse.
Synopsis
racadm raid resetconfig:<Controller FQDD> {-current|pending}
Input
–current <optional>: Performs the configuration right now.
RACADM Subcommand Details 91