CLI Guide

EMM.Slot.1:Enclosure.External.0-0:RAID.ChassisSlot.5-1
Status = Unknown
racadm raid get emms -o
Expander.Slot.0:Enclosure.Internal.0-0:RAID.ChassisIntegrated.2-1
Status = Ok
State = Ready
Name = Expander 0
PartNumber = 0TJ2VKA00
FirmwareVersion = 2.00
Expander.Slot.1:Enclosure.Internal.0-0:RAID.ChassisIntegrated.2-1
Status = Ok
State = Ready
Name = Expander 1
PartNumber = 0TJ2VKA00
FirmwareVersion = 2.00
EMM.Slot.0:Enclosure.External.0-1:RAID.ChassisSlot.5-1
Status = Ok
State = Ready
Name = EMM 0
PartNumber = 0W307KA00
FirmwareVersion = 1.05
EMM.Slot.1:Enclosure.External.0-1:RAID.ChassisSlot.5-1
Status = Ok
State = Ready
Name = EMM 1
PartNumber = 0W307KA00
FirmwareVersion = 1.05
EMM.Slot.0:Enclosure.External.0-0:RAID.ChassisSlot.5-1
Status = Failed
State = Failed
Name = EMM 0
PartNumber = 0W307KA00
FirmwareVersion = 1.05
EMM.Slot.1:Enclosure.External.0-0:RAID.ChassisSlot.5-1
Status = Unknown
State = Unknown
Name = EMM 1
PartNumber = 0W307KA00
FirmwareVersion = 1.05
get fans
Table 94. Details of get fans
Description Displays the status and attributes of the fans in the storage enclosure that are connected to chassis.
NOTE: To use this subcommand, you must have the CMC Login User privilege.
Synopsis
racadm raid get fans -o -p Status
racadm raid get fans -o
Input -o — The -o is used to display the fault-tolerant status of a enclosure.
Example
racadm raid get fans -o -p Status
Fan.Slot.0:Enclosure.External.0-1:RAID.ChassisSlot.5-1
FanOperationalStatus = Ok
Fan.Slot.1:Enclosure.External.0-1:RAID.ChassisSlot.5-1
FanOperationalStatus = Ok
Fan.Slot.2:Enclosure.External.0-1:RAID.ChassisSlot.5-1
FanOperationalStatus = Ok
RACADM Subcommand Details 83