CLI Guide
Input
• -m : <module> — Must be one of the following values:
• chassis — default state, if -m is not specified.
• server-n, where n=1–4
• switch-n, where n=1
• -c : <feature> — Must be one of the following values:
• ad — Reset Active Directory properties to the default value. The default setting is “disabled”.
• pcap — Reset Power Cap properties to the default value.
• flex — Reset FlexAddress properties to the default value. The default setting is “enabled”.
• dpse — Reset Dynamic Power Supply Engagement to the default value. The default setting is “disabled”.
NOTE: The –c option is valid with only <module=chassis>.
Example
• Perform reset of configuration data to defaults for server-1 module
racadm racresetcfg -m server-1
• Perform reset of power cap feature.
racadm racresetcfg -c pcap
• Perform reset of configuration data to default for switch-1 module
racadm racresetcfg -m switch-1
racresetpcie
Table 83. Details of racresetpcie
Description Resets the PCIe blade mapping in the chassis to factory defaults.
NOTE:
• To use this subcommand for CMC, you must have the Chassis Administrator
privilege.
• This command cannot run successfully, if any blade server is powered on.
Synopsis
racadm racresetpcie
raid
Table 84. Details of raid
Description Allows you to execute commands to control RAID arrays.
Synopsis
racadm raid
Example
• Monitor Health of Storage root node.
racadm raid get status
Storage Root Node Status : Ok
This command retrieves the controllers keys (FQDDs).
RACADM Subcommand Details
73