CLI Guide
• Power budget information - getpbinfo
• KVM information - getkvminfo
• NIC information (CMC module) - getniccfg
• Redundancy information - getredundancymode
• Trace log information - gettracelog
• RAC event log - getraclog
• System event log - getsel
Output The following information is displayed when the
racdumpsubcommand is processed:
• General system/RAC information
• Coredump
• Session information
• Process information
• Firmware build information
Example
racadm racdump
===============================================================================
General System/RAC Information
===============================================================================
CMC Information:
CMC Date/Time = Wed, 28 Nov 2007 11:55:49 PM
CMC Version = X08
Last Firmware Update = Wed Nov 21 21:37:56 2007
Hardware Version = 2
Current IP Address = 192.168.155.10
Current IP Gateway = 192.168.155.1
Current IP Netmask = 255.255.255.128
DHCP Enabled = 1
MAC Address = 00:55:AB:39:10:0F
Current DNS Server 1 = 0.0.0.0
Current DNS Server 2 = 0.0.0.0
DNS Servers from DHCP = 0
Register DNS CMC Name = 0
DNS CMC Name = cmc-servicetag
Current DNS Domain =
Chassis Information:
System Model = PowerEdge VRTX
System AssetTag = 00000
Service Tag =
Chassis Name = Dell Rack System
Chassis Location = [UNDEFINED]
Power Status = ON
===============================================================================
Session Information
===============================================================================
Type User IP Address Login Date/Time
SSH root 192.168.155.10 11/28/2007 23:40:53
KVM root 169.254.31.30 11/28/2007 18:44:51
===============================================================================
Sensor Information
===============================================================================
<senType> <Num> <sensorName> <status> <reading> <units> <lc>
<uc>
RACADM Subcommand Details