CLI Guide

Output The default output display shows the record number, timestamp, source, and description. The timestamp begins at
midnight, January 1 and increases until the system boots. After the system boots, the system’s timestamp is used.
Example
Record: 1
Date/Time: Dec 8 08:21:30
Source: ssnmgrd[175]
Description: root from 143.166.157.103: session timeout
sid 0be0aef4
getversion
Table 72. getversion
Description
Displays the current firmware version of various modules in the chassis, iDRAC version on the attached servers,
and whether the target device can be updated.
NOTE: To use this subcommand, you must have CMC Login User privilege.
Synopsis
racadm getversion
racadm getversion [-b | -c] [-m <module>]
racadm getversion -l [-m <module>] [-f <filter>]
Input
NOTE: The -b, -c and -l options are not available for CMC modules.
NOTE: The -l option requires that the Lifecycle Controller service is enabled on the servers. For
version information, see the RACADM Readme available at dell.com/support/manuals.
(none) — Displays the version information for all targets or devices.
<Server> <iDRAC Version> <Blade Type> <Gen>
<Updatable>
server-3 2.20.20.20 (41) PowerEdge M630
(VRTX) iDRAC8 Y
<Switch> <Model Name> <HW Version> <FW
Version>
switch-1 R1-PT VRTX 1Gb Pass-through
A00 1.0.0.8
<CMC> <CMC Version> <Updatable>
cmc-1 3.00.000.201609223282 Y
62 RACADM Subcommand Details