CLI Guide

Example
racadm getredundancymode
Redundant
getsel
Table 57. Details of getsel
Description Displays all sensor event log entries in the DRAC.
Synopsis racadm getsel -i [-A]
racadm getsel [-s <start>] [-c <count>] [-A] [-o] [-E] [-R] [--more]
If no arguments are specified, the entire log is displayed.
Input -A — Specifies output with no display headers or labels.
-c — Provides the number of records to be displayed.
-o — Displays each entry in the SEL in a single line.
-s — Specifies the starting record used for the display.
-E — Displays RAW SEL data with the other data for each entry.
-R — Displays only RAW SEL data for each entry.
-i — Displays the number of entries in the SEL.
--more — Displays one screen at a time and prompts the user to continue (similar to the UNIX more
command.)
NOTE: The -A, -E, -o, and -R options are deprecated.
Output
Record: 12
Date/Time: 11/20/2011 14:19:34
Source: system
Severity: Ok
Description: C: boot completed.
Example
racadm getsel
getsensorinfo
Table 58. Details of getsensorinfo
Description
Displays status of chassis sensors.
NOTE: To use this subcommand, you must have CMC Login User privilege.
Synopsis
racadm getsensorinfo
racadm getsensorinfo -c
56 RACADM Subcommand Details