getmodinfo
Table 48. getmodinfo
Description
Displays configuration and status information for all modules or a specified module (server, switch, CMC, fan unit,
blower, power supply unit, chassis, DVD, main-board, IO cable, and FPC cable) in the chassis.
To use this subcommand, you must have CMC Login User privilege.
NOTE: The service tag field is blank for modules that do not have service tags.
Synopsis
racadm getmodinfo [-m <module>] [-A]
Input
-m <module> — Specifies the module for which the configuration and status information is required. The default
command (no options) displays information about all the major components in the chassis.
<module> can be one of the following values:
server-n, where n = 1 to 4
switch-n, where n = 1
CMC-n, where n = 1 or 2
fan-n, where n = 1 to 6
blower-n, where n = 1 to 4
ps-n, where n = 1 to 4
chassis
dvd
main-board
io-cable
fpc-cable
storage
-A — Does not display the headers and labels in the output.