CLI Guide
Server-1-
A
10 GbE KR Not
Installed
10:98:36:AC:70:EB Not Installed Not
Installed
Server-2 Not
Installed
Not Present Not Installed Not Installed Not
Installed
Server-3-
A
Reserved Present
Switch-4 Not
Installed
Not Present Not Installed Not Installed Not
Installed
Switch-1 Not
Installed
Not Present Not Installed N/A N/A
NOTE: If the I/O Modules in slots 1 and 2 are absent and the getmacaddress -a and getmacaddress —c all
commands are run, the output is displayed as Not Installed in the following columns:
• <Presence>
• <NIC1 MAC Address>
• <NIC2 MAC Address>
getmodinfo
Table 48. getmodinfo
Description
Displays configuration and status information for all modules or a specified module (server, switch, CMC, fan unit,
blower, power supply unit, chassis, DVD, main-board, IO cable, and FPC cable) in the chassis.
To use this subcommand, you must have CMC Login User privilege.
NOTE: The service tag field is blank for modules that do not have service tags.
Synopsis
racadm getmodinfo [-m <module>] [-A]
Input
• -m <module> — Specifies the module for which the configuration and status information is required. The default
command (no options) displays information about all the major components in the chassis.
<module> can be one of the following values:
• server-n, where n = 1 to 4
• switch-n, where n = 1
• CMC-n, where n = 1 or 2
• fan-n, where n = 1 to 6
• blower-n, where n = 1 to 4
• ps-n, where n = 1 to 4
• chassis
• dvd
• main-board
• io-cable
• fpc-cable
• storage
• -A — Does not display the headers and labels in the output.
48 RACADM Subcommand Details