CLI Guide

[-q <sequence no.>] [-n <number of records>] [-r <start timestamp>]
[-e <end timestamp>]
Input
-i — Displays the number of records present in the active log. You cannot use this option with any
other option.
-c — The log type to filter the records. Provide multiple categories using a "," as the delimiter. The
value is case-insensitive. Valid Category values:
All
System
Storage
Updates
Audit
Config
-q - The sequence number from which the records must be displayed.
-n - Specifies the n Number of records to be displayed.
-r - Displays events that have occurred after this time. The time format is yyyy-mm-dd HH:MM:SS.
The time stamp must be provided within double quotes.
-e - Displays events that have occurred before this time. The time format is yyyy-mm-dd
HH:MM:SS. The time stamp must be provided within double quotes.
-f <filename> - Specifies the file location and name where the chassis log is exported.
-a <name> - Specifies the FTP Server IP address or FQDN, user name, and password.
-d <path> - Specifies the path to the file on the FTP server.
-l <location> - Specifies the location of the network share or area on file system where chassis log is
exported. Two types of network shares are supported:
— SMB mounted path: //<ipaddress or domain name>/<share_name>/<path_to_image>
— NFS mounted path: <ipaddress>:/<path_to_image>.
-u <user> — Specifies the user name for accessing the FTP Server, or Domain and User Name for
accessing network share location.
-p <password> — Specifies the password for accessing the FTP Server or Share location.
-s — Filters records based on severity. Provide multiple severities using a comma (,) as the
delimiter. The values are not case-sensitive. The valid severity values are:
1. Warning
2. Critical
3. Info
-b — The subcategory used to filter the records. Provide multiple subcategories using a comma (,)
as the delimiter. The values are not case-sensitive. The valid subcategories are:
CPUA: Proc Absent
MEM: Memory
UEFI: UEFI Event
FC: Fiber Channel
ENC: Storage Enclosure
SYS: System Info
LNK: Link Status
BAT: Battery Event
RSI: Remote Service
OSE: OS Event
VRM: Virtual Console
PSU: Power Supply
Log: Log event
RDU: Redundancy
FCD: Feature Card
CMC: Chassis Management Controller
CTL: Storage Controller
CPU: Processor
22
RACADM Subcommand Details