CLI Guide

cfgChassisRedundancyPolicy (Read/Write)
Table 315. Details of cfgChassisRedundancyPolicy
Description Sets the redundancy policy of the chassis.
Legal Values 0 (no redundancy)
1 (AC redundancy)
2 (power supply redundancy)
Default 0 (no redundancy)
cfgChassisDynamicPSUEngagementEnable (Read/Write)
Table 316. Details of cfgChassisDynamicPSUEngagementEnable
Description Enables or disables dynamic engagement.
Legal Values 0 (disabled)
1 (enabled)
Default 0 (disabled)
cfgChassisInMaxPowerCapacity (Read Only)
Table 317. Details of cfgChassisInMaxPowerCapacity
Description Indicates the total chassis power budget (in watts) available for chassis operation.
Legal Values None
Default None
cfgChassisInRedundancyReserve (Read Only)
Table 318. Details of cfgChassisInRedundancyReserve
Description Indicates the amount of redundant power (in Watt) in reserve that can be utilized in the event of
an AC grid or PSU failure. This value is 0 if the Redundancy Policy is set to 0 (no redundancy).
Legal Values 0 (disabled)
1 (enabled)
Default None
cfgChassisInPowerServerAllocation (Read Only)
Table 319. Details of cfgChassisInPowerServerAllocation
Description Indicates (in Watt) the cumulative power allocated to servers. There is no default as this parameter
is very specific to the particular customer configuration.
Legal Values None
Default None
162 CMC Property Database Group and Object Descriptions