CLI Guide
cfgSerialBaudRate (Read/Write)
Table 190. Details of cfgSerialBaudRate
Description Sets the baud rate on the serial port.
Legal Values
2400, 4800, 9600, 19200, 28800, 38400, 57600,115200
Default
115200
cfgSerialConsoleEnable (Read/Write)
Table 191. Details of cfgSerialConsoleEnable
Description Enables or disables the RAC or CMC serial console interface.
Legal Values • 1 (TRUE)
• 0 (FALSE)
Default
1
cfgSerialConsoleIdleTimeout (Read/Write)
Table 192. Details of cfgSerialConsoleIdleTimeout
Description The maximum number of seconds to wait before an idle serial
session is disconnected.
Legal Values • 0 = No timeout
• 60 – 10800
Default
1800
cfgSerialConsoleNoAuth (Read/Write)
Table 193. Details of cfgSerialConsoleNoAuth
Description Enables or disables the RAC or CMC serial console login
authentication.
Legal Values • 0 (enables serial login authentication)
• 1 (disables serial login authentication)
Default 0
cfgSerialConsoleCommand (Read/Write)
Table 194. Details of cfgSerialConsoleCommand
Description Specifies a serial command that is executed after a user logs into
the serial console interface.
Legal Values
A string representing a valid serial command. For example,
connect server-1.
Default <blank>
130 CMC Property Database Group and Object Descriptions