Users Guide
– Chassis Overview > Chassis Controller > Troubleshooting.
– Chassis Overview > Server Overview > Troubleshooting.
NOTE: Only servers can be selected on this page.
– Chassis Overview > I/O Module Overview > Troubleshooting.
– Storage > Troubleshooting > Identify.
NOTE: Physical disk per enclosures, virtual disks per enclosures, and external storage component LED can be selected on
this page.
To enable blinking of a component LED, select the Select/Deselect All option corresponding to the physical disk drive or virtual disk or
enclosures, and then click Blink. To disable blinking of a component LED, clear the Select/Deselect All option corresponding to the LED,
and then click Unblink.
Conguring LED Blinking Using RACADM
Open a serial/Telnet/SSH text console to CMC, log in, and type:
racadm setled -m <module> [-l <ledState>], where <module> species the module whose LED you want to congure.
Conguration options:
• server-n where n = 1-4
• switch-1
• cmc-active
and <ledState> species whether or not the LED should blink. Conguration options:
• 0 — not blinking (default)
• 1 — blinking
racadm raid <operation> <component FQDD>, where the operation value is blink or unblink, and the FQDD is for the
component's physical disk drive, virtual disk and enclosures.
Conguring CMC Properties
You can congure CMC properties such as power budgeting, network settings, users, and SNMP and email alerts using the web interface
or RACADM commands.
Conguring iDRAC Launch Method Using CMC Web
Interface
To congure the iDRAC launch method from the General Chassis Settings page:
1 In the left pane, click Chassis Overview > Setup.
The General Chassis Settings page is displayed.
2 In the drop-down menu for the iDRAC Launch Method property, select IP Address or DNS.
3 Click Apply.
NOTE
: A DNS-based launch is used for any particular iDRAC only if:
• The chassis setting is DNS.
• CMC has detected that the specic iDRAC is congured with a DNS
name.
38 Installing and Setting Up CMC