Users Guide
• Re-insert the CMC module to chassis, after the CMC is in online state, the default credential is active (User Name: root/ Password:
calvin)
• Login to CMC using default credential and change the password
• After the password is changed, remove CMC module and jumper from Password recovery header
• Re-insert the CMC module to chassis, after the CMC is in online state, the new credential is active
Gathering Conguration Information, Chassis Status,
and Logs Using RACDUMP
The racdump subcommand provides a single command to get comprehensive chassis status, conguration state information, and the
historic event logs.
The racdump subcommand displays the following information:
• General system/RAC information
• CMC information
• Chassis information
• Session information
• Sensor information
• Firmware build information
Supported Interfaces
• CLI RACADM
• Remote RACADM
• Telnet RACADM
racdump includes the following subsystems and aggregates the following RACADM commands. For more information about racdump,
see the RACADM Command Line Reference Guide for CMC in PowerEdge VRTX.
Table 42. Racadm commands for subsystems
Subsystem RACADM Command
General System/RAC information
getsysinfo
Session information
getssninfo
Sensor information
getsensorinfo
Switches information (IO Module)
getioinfo
Mezzanine card information (Daughter card)
getdcinfo
All modules information
getmodinfo
Power budget information
getpbinfo
KVM information
getkvminfo
NIC information (CMC module)
getniccfg
Redundancy information
getredundancymode
Trace log information
gettracelog
RAC event log
getraclog
Troubleshooting and Recovery 215