Users Guide
Viewing Temperature Probe Status and attributes of the
Enclosure
Temperature probe status displays the status of the temperature sensors of the enclosure. Sensors contain a status value that is unique
from the enclosure. You can have up to four temperature sensors or probes and enclosure rmware creates a status for each sensor. You
must have CMC Login privileges to view probe status.
Viewing Temperature Probe Status and attributes of the Enclosure Using
Web Interface
To view the temperature probe status and attributes of the enclosure:
Click Chassis Overview → Storage → Enclosures → Properties. The Enclosures page provides the health and attributes for the
temperature probe of the enclosure in the chassis. Expand the external enclosure to view the status for the PSU of the enclosures. For
more information, see the CMC Online Help.
Viewing Temperature Probe Attributes of the Enclosure Using RACADM
To view temperature probe attributes of the Enclosure, use racadm raid get tempprobes -o command. For more information, see
the
Chassis Management Controller for PowerEdge VRTX RACADM Command Line Reference Guide available at dell.com/cmcmanuals.
Setting the Temperature Warning Threshold of the Enclosure
Temperature warning threshold allows you to change the threshold at which an enclosure temperature reports as warning.
NOTE
:
• Error is displayed if you enter an invalid value.
• Initially the value which is saved in the rmware is displayed.
• You must have Chassis Conguration Privileges to set asset tag and asset name of the enclosure.
Setting the Temperature Warning Threshold of the Enclosure Using Web
Interface
To set temperature warning threshold of the enclosure:
Click Chassis Overview → Storage → Enclosures → Setup. Select the enclosure from the Enclosure drop-down menu, then enter the
appropriate values for minimum and maximum for warning threshold temperatures of temp sensor 2 and 3. Type the Asset tag and Asset
name in the appropriate elds, and then click Apply. For more information, see the CMC Online Help.
Setting Temperature Warning Threshold of the Enclosure Using RACADM
To set the minimum warning threshold of temperature probe in the enclosure, use racadm raid set
tempprobes:TempSensor.Embedded.0:Enclosure.External.1-0:RAID.ChassisSlot.6-1 –p
MinimumWarningThreshold <value> command.
208