Users Guide
• Applying Virtual Adapter Access Policy To Virtual Disks
• Modifying Virtual Disk Properties Using CMC Web Interface
• Enclosure Management Module
• Viewing Enclosure Properties Using CMC Web Interface
Viewing Status of the Storage Components
To view the status of the storage components:
1 In the left pane, click Chassis Overview > Storage > Properties > Storage Overview.
2 On the Storage Overview page, you can:
• View the graphic summary of the physical disk drives installed in the chassis and their status.
• View the summary of all the storage components with links to their respective pages.
• View the used capacity and total capacity of the storage.
• View controller information.
NOTE: In case of a fault-tolerant controller, the name format is: Shared <
PERC number
> (Integrated <number>). For
example, the active controller is Shared PERC8 (Integrated 1) and the peer controller is Shared PERC8 (Integrated 2).
NOTE: If the secondary PERC is disabled, the name is displayed as Disabled PERC (Integrated 2).
• View recently-logged storage events.
NOTE: For more information, see the
Online Help
.
Viewing the Storage Topology
To view the Storage topology:
1 In the left pane, click Chassis Overview > Storage > Properties > Topology.
2 On the Topology page, click the <controller name> to view the respective pages.
NOTE
: You can view the name of the controller that is active in controlling the storage devices associated with this CMC
and also the passive controller acting as a stand-by.
3 Under each installed controllers, click the links View Virtual Disks, <enclosure name>, and View Physical Disks to open the
respective pages.
Viewing Fault-tolerant Troubleshooting Information of
SPERC Using CMC Web Interface
To view the attributes that indicate the correct functioning of fault-tolerant features of a SPERC:
1 In the left pane, click Chassis Overview > Storage > Troubleshooting > Setup Troubleshooting.
The Storage Setup Troubleshooting page is displayed.
2 On the Storage Setup Troubleshooting page, you can:
• Click to view the following attributes when the integrated controller is in fault-tolerant mode:
– Two Shared PERCs detected.
– Two expanders detected
– Shared PERCs and expanders correctly cabled
– Correct Firmware on Shared PERCs
– Correct Firmware on Expanders
192