Users Guide
Executing Power Control Operations on the Chassis
CMC enables you to remotely perform several power management actions, such as an orderly shutdown on the entire chassis (chassis,
servers, IOM, and PSUs).
NOTE: To perform power management actions, you must have the Chassis Conguration Administrator privilege.
Executing Power Control Operations on the Chassis Using
Web Interface
To execute power control operations on the chassis using the CMC web interface:
1 In the left pane, click Chassis Overview > Power > Control.
The Chassis Power Control page is displayed.
2 Select one of the following power control operations.
For information about each option, see the Online Help.
• Power On System
• Power O System
• Power Cycle System (cold boot)
• Reset CMC (warm boot)
• Non-Graceful Shutdown
3 Click Apply.
A dialog box appears asking you for a conrmation.
4 Click OK to perform the power management action (for example, cause the system to reset).
Executing Power Control Operations on the Chassis Using
RACADM
Open a serial/Telnet/SSH text console to CMC, log in, and type:
racadm chassisaction -m chassis <action>
where <action> is powerup, powerdown, powercycle, nongraceshutdown, or reset.
Executing Power Control Operations on a Server
You can remotely perform power management actions for multiple servers at a time or an individual server in the chassis.
NOTE
: The modular blade servers are in throttle state during CMC reboot or failover.
NOTE: To perform power management actions, you must have the Chassis Conguration Administrator privilege.
Managing and Monitoring Power 189