Users Guide
where, <fabricName> = A or iDRAC and <state> = 0 or 1
0 is disable and 1 is enable.
To enable or disable slots, use the following RACADM command:
racadm setflexaddr [-i <slot#> <state>
where, <slot#> = 1 or 4 and <state> = 0 or 1
0 is disable and 1 is enable.
For more information about the setexaddr command, see the Chassis Management Controller for PowerEdge VRTX RACADM
Command Line Reference Guide.
NOTE: If you purchase the FlexAddress or FlexAddressPlus feature with your Dell PowerEdge VRTX, it is preinstalled and
enabled for all slots and fabrics. To purchase this feature, contact Dell at dell.com.
NOTE: By using the racresetcfg subcommand, you can reset the Flex Address of a CMC to its factory-default setting, which
is “disabled”. The RACADM syntax is:
racadm racresetcfg -c flex
For more information about the FlexAddress-related RACADM commands and data about the other factory-default properties,
see the
Chassis Management Controller for PowerEdge VRTX RACADM Command Line Reference Guide
available at dell.com/
cmcmanuals.
Viewing World Wide Name or Media Access Control
Addresses
The WWN/MAC Summary page allows you to view the World Wide Name (WWN) conguration and Media Access Control (MAC)
address of a slot in the chassis.
Fabric Conguration
The Fabric Conguration section displays the type of Input/Output fabric that is installed for Fabric A. A green check mark indicates that
the fabric is enabled for FlexAddress. The FlexAddress feature is used to deploy chassis assigned and slot persistent WWN/MAC addresses
to various fabrics and slots within the chassis. This feature is enabled on a per-fabric and per-slot–basis.
NOTE
: For more information about the FlexAddress feature, see About FlexAddress.
Viewing WWN or MAC Address Information
You can view the WWW/MAC address inventory of Network Adapters for each server slot or all servers in a chassis. The inventory includes
the following:
• Fabric Conguration
NOTE
:
– Fabric A displays the type of the Input/Output fabric installed. If Fabric A is enabled, unpopulated slots display chassis-assigned
MAC addresses for Fabric A.
– iDRAC management controller is not a fabric, but its FlexAddress is considered as a fabric.
– IF the check box associated with a component is selected, it implies that the fabric is enabled for FlexAddress or
FlexAddressPlus.
Using FlexAddress and FlexAdress Plus 167