Users Guide
Conguring Email Alert Settings
When CMC detects a chassis event, such as an environmental warning or a component failure, it can be congured to send an email alert
to one or more email addresses.
Congure the SMTP email server to accept relayed emails from the CMC IP address, a feature which is normally turned o in most mail
servers due to security concerns. For instructions to congure in a secure manner, see the documentation that was provided with the
SMTP server.
NOTE: If your mail server is Microsoft Exchange Server 2007, make sure that iDRAC domain name is congured for the mail
server to receive the email alerts from iDRAC.
NOTE: Email alerts support both IPv4 and IPv6 addresses. The DRAC DNS Domain Name must be specied when using IPv6.
If your network has an SMTP server that releases and renews IP address leases periodically, and the addresses are dierent, then there is a
duration when this property setting does not work due to change in the specied SMTP server IP address. In such cases, use the DNS
name.
Conguring Email Alert Settings Using CMC Web Interface
To congure the email alert settings using Web interface:
1 In the left pane, click Chassis Overview > Alerts > E-mail Alert Settings.
2 Specify the SMTP email server settings and the email addresses to receive the alerts. For information about the eld descriptions, see
the
Online Help.
3 Click Apply to save the settings.
4 Click Send under Test E-mail to send a test email to the specied email alert destination.
Conguring EMail Alert Settings Using RACADM
To send a test email to an email alert destination using RACADM:
1 Open a serial/Telnet/SSH text console to CMC and log in.
2 Enable alert generation:
racadm config -g cfgAlerting -o cfgAlertingEnable 1
NOTE
: Only one lter mask may be set by both SNMP and email alerting. If you have already set a lter mask, do not
perform the task in step 3.
3 Specify the events for which alerts must be generated:
racadm config -g cfgAlerting -o cfgAlertingFilterMask <mask value>
where <mask value> is a hexadecimal value between 0x0 and 0x and must be expressed with the leading 0x characters. The
Event Traps Filter Masks table provides lter masks for each event type. For instructions about calculating the hex value for the lter
mask you want to enable, see step 3 in the
Conguring SNMP Trap Alert Destinations Using RACADM.
4 Enable email alert generation:
racadm config -g cfgEmailAlert -o cfgEmailAlertEnable 1 -i <index>
where <index> is a value between 1–4. CMC uses the index number to distinguish up to four destination email addresses that can be
congured.
5 Specify a destination email address to receive the email alerts:
racadm config -g cfgEmailAlert -o cfgEmailAlertAddress <email address> -i <index>
where <email address> is a valid email address, and <index> is the index value you specied in step 4.
126