Release Notes
Known Issues
Flex address disabled after racresetcfg of CMC
Description XWKGY_Intel10G card shows Flex address disabled after racresetcfg of CMC in Network Device page and
OS.
Resolution Virtual reseat or physical reseat of the server
Versions/Systems
aected
All CMC versions including CMC 3.20 for Dell PowerEdge VRTX and PowerEdge servers with iDRAC7 or earlier.
RAID-related operations might take longer to report
status
Description After Shared PERC8 controller update, RAID-related operations may take longer to report status.
Resolution Wait for the operation status to report.
Versions/Systems
aected
CMC version 2.01 or later for Dell PowerEdge VRTX.
Error occurs while importing CMC conguration le
Description
An error occurs while importing CMC conguration le using local or remote RACADM.
Resolution This issue occurs when IPv6 is enabled or disabled from the conguration le. Enable or disable IPv6 using the
command, racadm config -g cfgIPv6LanNetworking -o cfgIPv6Enable 0.
Versions/Systems
aected
CMC Version 2.0 or later for Dell PowerEdge VRTX
Chassis overview health tab does not display alert
Description
At times when foreign drives are inserted, the Chassis Overview Health tab does not display the alert, “Foreign
Conguration was detected on Physical Disk”.
Resolution None
The alert is not displayed only at times. But, the functionality for foreign conguration is not aected.
Versions/Systems
aected
All CMC versions including CMC 3.00 for Dell PowerEdge VRTX
8
Known Issues 15