CLI Guide

— cmc-active
— chassis
-l <ledstate> - Species whether the LED should blink.
<ledstate> can be one of the following:
– 0 — no blinking
– 1 — blinking
Example
racadm setled -m server-1 -1 1
LED state was set successfully.
NOTE: The setled command generates an error when used on the extension slot of a multi-slot
server.
racadm setled -m server-9 -1 1
ERROR: Server in slot 9 is an extension of the server in slot 1.
set enclosure
Table 121. Details of set enclosure
Description Sets the asset tag and asset name of the enclosures.
NOTE: Set enclosure is used for the storage expansion feature when available with shared external
PERCs.
NOTE: You cannot modify the asset names for internal enclosures.
Synopsis
racadm raid set enclosures: Enclosure.External.0-0:RAID.ChassisSlot.5-1 –p
AssetTag <value>
racadm raid set enclosures: Enclosure.External.0-0:RAID.ChassisSlot.5-1 –p
AssetName <value>
Input
-pSpecies the property of the enclosure to be modied.
setniccfg
Table 122. Details of setniccfg
Description Sets the iDRAC IP address. It displays an error message if the requested operation could not be
performed, or a success message, if the operation is completed successfully.
To use this subcommand, you must have the Congure iDRAC privilege.
NOTE: The terms NIC and Ethernet management port may be used interchangeably.
Synopsis
racadm setniccfg -d
racadm setniccfg -d6
racadm setniccfg -s <IPv4Address> <netmask> <IPv4 gateway>
racadm setniccfg -s6 <IPv6 Address> <IPv6 Prefix Length> <IPv6
Gateway
>
98 RACADM Subcommand Details