CLI Guide
— cmc-active
— chassis
• -l <ledstate> - Species whether the LED should blink.
<ledstate> can be one of the following:
– 0 — no blinking
– 1 — blinking
Example
• racadm setled -m server-1 -1 1
LED state was set successfully.
NOTE: The setled command generates an error when used on the extension slot of a multi-slot
server.
• racadm setled -m server-9 -1 1
ERROR: Server in slot 9 is an extension of the server in slot 1.
set enclosure
Table 121. Details of set enclosure
Description Sets the asset tag and asset name of the enclosures.
NOTE: Set enclosure is used for the storage expansion feature when available with shared external
PERCs.
NOTE: You cannot modify the asset names for internal enclosures.
Synopsis
racadm raid set enclosures: Enclosure.External.0-0:RAID.ChassisSlot.5-1 –p
AssetTag <value>
racadm raid set enclosures: Enclosure.External.0-0:RAID.ChassisSlot.5-1 –p
AssetName <value>
Input
-p — Species the property of the enclosure to be modied.
setniccfg
Table 122. Details of setniccfg
Description Sets the iDRAC IP address. It displays an error message if the requested operation could not be
performed, or a success message, if the operation is completed successfully.
To use this subcommand, you must have the Congure iDRAC privilege.
NOTE: The terms NIC and Ethernet management port may be used interchangeably.
Synopsis
• racadm setniccfg -d
• racadm setniccfg -d6
• racadm setniccfg -s <IPv4Address> <netmask> <IPv4 gateway>
• racadm setniccfg -s6 <IPv6 Address> <IPv6 Prefix Length> <IPv6
Gateway
>
98 RACADM Subcommand Details