CLI Guide

Physical Disk 0:0:6 AS09 Disk.Bay.
6:Enclosure.Internal.0-0:RAID.ChassisIntegrated.1-1
Physical Disk 0:0:7 AS09 Disk.Bay.
7:Enclosure.Internal.0-0:RAID.ChassisIntegrated.1-1
Physical Disk 0:0:8 AS09 Disk.Bay.
8:Enclosure.Internal.0-0:RAID.ChassisIntegrated.1-1
Physical Disk 0:0:9 AS09 Disk.Bay.
9:Enclosure.Internal.0-0:RAID.ChassisIntegrated.1-1
-b - Displays the server's current BIOS version (default is iDRAC version).
-c - Displays the server's current CPLD version.
-l - Displays the rmware versions Lifecycle Controller components.
-f <lter> - Filters the components. Must be used with -1 and be one of the following values:
bios: BIOS
idrac: iDRAC
usc: Unied Server Congurator (Lifecycle Controller)
diag: 32-bit Diagnostics
drivers: OS Driver Package
nic-x: Network Interface card. See -l output for possible values of x.
raid-x: RIAD Controller. See -l output for possible values of x.
-m <module> - Species the module or device for which you must retrieve the version information.
<module> is one of the following:
server-n, where n = 1 to 4. For example, cmc-2.
switch-n, where n = 1
CMC-n, where n = 1 or 2
mainboard
perc
expander
hdd
perc-fqdd, where fqdd is FQDD of the PERC.
expander-fqdd, where fqdd is FQDD of the Storage Expander.
hdd-fqdd, where fqdd is FQDD of the HDD.
NOTE
: The Linux shell script does not support the characters—$ (dollar),` (back quote), \ (forward
slash), & (ampersand), ( (open bracket), ) (Close bracket), = (equal), | (Pipe), ; (semi colon)," (Double
quote), ' (single quote), < (less than), and > (greater than).
Example
Retrieve the version for a server 4
racadm getversion -m server-4
Retrieve the Lifecycle Controller component versions for servers 1 and 3:
racadm getversion -l -m server-1 -m server-3
Retrieve the Lifecycle Controller BIOS versions for servers 1 and 3:
racadm getversion -l -m server-1 -m server-3 -f bios
Retrieve the version for all modules:
racadm getversion
Retrieve the iDRAC version in all the servers that are attached to the chassis:
racadm getversion -f idrac
62 RACADM Subcommand Details