CLI Guide

System Model = PowerEdge VRTX
System AssetTag = 00000
Service Tag =
Express Service Code =
Chassis Name = CMC-
Chassis Location = [UNDEFINED]
Chassis Midplane Version = 1.0
Power Status = ON
System ID = 1487
Examples
racadm getsysinfo -d
racadm getsysinfo -c
racadm getsysinfo -A
racadm getsysinfo -4
racadm getsysinfo -6
gettracelog
Table 70. Details of gettracelog
Description Lists all the trace log entries in CMC.
Synopsis
racadm gettracelog -i [-A]
racadm gettracelog [-s <start>] [-c <count>] [--more] [-A] [-o]
Input
-i - Displays the number of entries in iDRAC trace log.
--more - Displays one screen at a time and prompts the user to continue (similar to the UNIX more command).
-o - Displays each entry in a single line.
-c - Species the number of records to display.
-s - Species the starting record to display.
-A - Does not display headers or labels.
NOTE: The -A and -o options are deprecated.
Output The default output display shows the record number, timestamp, source, and description. The timestamp begins at
midnight, January 1 and increases until the system boots. After the system boots, the system’s timestamp is used.
Example
Record: 1
Date/Time: Dec 8 08:21:30
Source: ssnmgrd[175]
Description: root from 143.166.157.103: session timeout
sid 0be0aef4
getversion
Table 71. getversion
Description
Displays the current rmware version of various modules in the chassis, iDRAC version on the attached servers, and
whether the target device can be updated.
60 RACADM Subcommand Details