CLI Guide

Input
-A Species output with no display headers or labels.
-c — Provides the number of records to be displayed.
-o — Displays each entry in the SEL in a single line.
-s Species the starting record used for the display.
-E — Displays RAW SEL data with the other data for each entry.
-R — Displays only RAW SEL data for each entry.
-i — Displays the number of entries in the SEL.
--more — Displays one screen at a time and prompts the user to continue (similar to the UNIX more command.)
NOTE: The -A, -E, -o, and -R options are deprecated.
Output
Record: 12
Date/Time: 11/20/2011 14:19:34
Source: system
Severity: Ok
Description: C: boot completed.
Example
racadm getsel
getsensorinfo
Table 57. Details of getsensorinfo
Description
Displays status of chassis sensors.
NOTE: To use this subcommand, you must have CMC Login User privilege.
Synopsis
racadm getsensorinfo
racadm getsensorinfo -c
Table 58. Examples
<Sensor Name> <Status> <Reading> <LW> <LC> <UW> UC
Fan-1 OK 0 840 600 N/A N/A
Fan-2 OK 0 840 600 N/A N/A
Fan-3 OK 4037 840 600 N/A N/A
Fan-4 OK 4045 840 600 N/A N/A
Fan-5 OK 4107 840 600 N/A N/A
Fan-6 OK 0 840 600 N/A N/A
Blower-1 N/A 0 3000 2250 N/A N/A
Blower-2 N/A 0 3000 2250 N/A N/A
Blower-3 N/A 0 3000 2250 N/A N/A
RACADM Subcommand Details 55