CLI Guide
getractime
Table 54. Details of getractime
Description Displays the current iDRAC time.
Synopsis
• racadm getractime [-d]
• racadm getractime [-d][-z]
• racadm getractime [-n]
Input
• -d — Displays the time in the format, yyyymmddhhmmss.mmmmmms.
• -z — Displays timezone. This option is specic to CMC only.
• -n — Displays NTP peer information. This option is specic to CMC only.
NOTE: If no options are provided, the getractime subcommand displays the time in a common readable
format.
Output The current iDRAC time is displayed.
Example
• racadm getractime
Thu Dec 8 20:15:26 2005
• racadm getractime -d
20051208201542.000000
getredundancymode
Table 55. Details of getredundancymode
Description Displays the redundancy status (Redundant or Non-Redundant) of
the CMC.
To use this subcommand, you must have CMC Login User privilege.
Synopsis
racadm getredundancymode
Example
racadm getredundancymode
Redundant
getsel
Table 56. Details of getsel
Description Displays all sensor event log entries in the DRAC.
Synopsis
• racadm getsel -i [-A]
• racadm getsel [-s <start>] [-c <count>] [-A] [-o] [-E] [-R] [--more]
If no arguments are specied, the entire log is displayed.
54 RACADM Subcommand Details