-l <location> - Species the location of the network share or area on le system where chassis log is
exported. Two types of network shares are supported:
— SMB mounted path: //<ipaddress or domain name>/<share_name>/<path_to_image>
— NFS mounted path: <ipaddress>:/<path_to_image>.
-u <user> — Species the user name for accessing the FTP Server, or Domain and User Name for
accessing network share location.
-p <password> — Species the password for accessing the FTP Server or Share location.
-s — Filters records based on severity. Provide multiple severities using a comma (,) as the delimiter.
The values are not case-sensitive. The valid severity values are:
1. Warning
2. Critical
3. Info
-b — The subcategory used to lter the records. Provide multiple subcategories using a comma (,)
as the delimiter. The values are not case-sensitive. The valid subcategories are:
CPUA: Proc Absent
MEM: Memory
UEFI: UEFI Event
FC: Fiber Channel
ENC: Storage Enclosure
SYS: System Info
LNK: Link Status
BAT: Battery Event
RSI: Remote Service
OSE: OS Event
VRM: Virtual Console
PSU: Power Supply
Log: Log event
RDU: Redundancy
FCD: Feature Card
CMC: Chassis Management Controller
CTL: Storage Controller
CPU: Processor
CBL: Cable
JCP: Job Control
VF: vFlash Media
IPA: DRAC IP Address
SUP: FW Update Job
RFM: FlexAddress SD
PSUA: PSU Absent
PCI: PCI Device
LIC: Licensing
RFL : IDSDM Media
NIC : NIC Cong
VFL : vFlash Event
TMPS : Temperature Statistics
DIS : Auto-Discovery
STOR : Storage
SEL : Sys Event Log
OSD : OS Deployment
SRD : Software RAID