CLI Guide
cfgAlertingEnable
Table 333. Details of cfgAlertingEnable
Description Enables or disables event traps on the CMC.
Legal Values
• 1 (true)
• 0 (false)
Default None
To use this object property, you must have the Chassis Conguration Administrator privilege.
cfgAlertingSourceEmailName
Table 334. Details of cfgAlertingSourceEmailName
Description Species the e-mail address used to send e-mail notications when an event occurs.
Legal Values Valid e-mail address
Default None
Examples
racadm getconfig -g cfgAlerting -o cfgAlertingSourceEmailName
racadm config -g cfgAlerting -o cfgAlertingSourceEmailName user@home.com
Object value modified successfully.
To use this object property, you must have Chassis Conguration Administrator and Test Alert User privileges.
cfgIPv6LanNetworking
This group is used to congure the IPv6 over LAN networking capabilities.
Use this object with the cong or getcong subcommands.
To use this object property for CMC, you must have the Chassis Conguration Administrator privilege.
The following sections provide information about the objects in the cfgIPv6LanNetworking group.
CMC Property Database Group and Object Descriptions
177