CLI Guide

# cfgChassisInPowerServerAllocation=0 W
# cfgChassisInfrastructureInPowerAllocation=51 W
# cfgChassisTotalInPowerAvailable=0 W
# cfgChassisStandbyInPowerCapacity=0 W
# cfgChassisPowerClear=******** (Write-Only)
# cfgChassisPowerClearTimestamp=18:00:00 12/31/1969
cfgChassisServerBasedPowerMgmtMode=0
cfgChassisPowerButtonEnable=1
cfgChassisAllow110VACOperation=0
cfgChassisMaxPowerConservationMode=0
cfgChassisPerformanceOverRedundancy=1
# cfgSystemEnergyConsumptionClear = ****(Write-Only)
cfgChassisServerBasedPowerMgmtMode=0
racadm config -g cfgChassisPower o cfgChassisPowerClear 1
Clears cfgChassisMinPower and cfgChassisPeakPower.
cfgChassisServerBasedPowerMgmtMode
Table 326. Details of cfgChassisServerBasedPowerMgmtMode
Description Indicates the server-based power management mode of a chassis.
Legal Values
0 (disabled)
1 (enabled)
Default 0 (disabled)
cfgChassisPowerCapBTU (Read/Write)
Table 327. Details of cfgChassisPowerCapBTU
Description Indicates the maximum power consumption limit (in BTU/hr) for the
entire chassis. The command generates an error if server throttling
is necessary to achieve the power goal based on the value for this
setting.
Legal Values 9264 - 56931 BTU/hr
Default 43221 BTU/hr
cfgChassisACPowerRecoveryDisable
Table 328. Details of cfgChassisACPowerRecoveryDisable attribute
Description
If AC power recovery is disabled, the chassis is powered o after power outage is restored.
Legal Values
0 — Enable
1 — Disable
174 CMC Property Database Group and Object Descriptions