CLI Guide
cfgChassisDynamicPSUEngagementEnable (Read/Write)
Table 315. Details of cfgChassisDynamicPSUEngagementEnable
Description Enables or disables dynamic engagement.
Legal Values
• 0 (disabled)
• 1 (enabled)
Default 0 (disabled)
cfgChassisInMaxPowerCapacity (Read Only)
Table 316. Details of cfgChassisInMaxPowerCapacity
Description Indicates the total chassis power budget (in watts) available for chassis operation.
Legal Values None
Default None
cfgChassisInRedundancyReserve (Read Only)
Table 317. Details of cfgChassisInRedundancyReserve
Description Indicates the amount of redundant power (in Watt) in reserve that can be utilized in the event of an
AC grid or PSU failure. This value is 0 if the Redundancy Policy is set to 0 (no redundancy).
Legal Values 0 (disabled)
1 (enabled)
Default None
cfgChassisInPowerServerAllocation (Read Only)
Table 318. Details of cfgChassisInPowerServerAllocation
Description Indicates (in Watt) the cumulative power allocated to servers. There is no default as this parameter
is very specic to the particular customer conguration.
Legal Values None
Default None
CMC Property Database Group and Object Descriptions 171