CLI Guide
Example
racadm getconfig -g cfgStandardSchema -i 1
NOTE: -i <number> is for the index.
# cfgSSADRoleGroupIndex=1
cfgSSADRoleGroupName=
cfgSSADRoleGroupDomain=
cfgSSADRoleGroupPrivilege=
$ config -g cfgStandardSchema -i 1 -o cfgSSADRoleGroupName Charlie
Object value modified successfully
Table 297. Bit masks for Role Group privileges
Role Group Privilege Bit Mask
Login to iDRAC 0x00000001
Congure iDRAC 0x00000002
Congure Users 0x00000004
Clear Logs 0x00000008
Execute Server Control Commands 0x00000010
Access Virtual Console 0x00000020
Access Virtual Media 0x00000040
Test Alerts 0x00000080
Execute Debug Commands 0x00000100
cfgChassisPower
This group is applicable only to CMC and contains parameters to display or congure power for the chassis.
Use this object with the cong or getcong subcommands.
To use this object property, you must have the Chassis Conguration Administrator privilege.
The following sections provide information about the objects in the cfgChassisPower group.
NOTE
: While conguring chassis power from a le, update the value for one chassis power cap property and remove the values
for the other chassis power cap properties or, update the last percentage value as it is applicable to all chassis power cap
properties. The chassis power cap properties are: cfgChassisPowerCap, cfgChassisPowerCapF,
cfgChassisPowerCapBTU, cfgChassisPowerCapFBTU, cfgChassisPowerCapPercent, and
cfgChassisPowerCapFPercent.
CMC Property Database Group and Object Descriptions 165