CLI Guide
cfgSerialSshEnable (Read/Write)
Table 196. Details of cfgSerialSshEnable
Description Enables or disables the secure shell (SSH) interface on CMC.
Legal Values
• 1 (TRUE)
• 0 (FALSE)
Default 1
Example
racadm getconfig -g cfgSerial
cfgSerialBaudRate=115200
cfgSerialConsoleEnable=1
cfgSerialConsoleQuitKey=^\
cfgSerialConsoleIdleTimeout=1800
cfgSerialConsoleNoAuth=0
cfgSerialConsoleCommand=
cfgSerialConsoleColumns=0
cfgSerialHistorySize=8192
cfgSerialTelnetEnable=0
cfgSerialSshEnable=1
cfgSerialTelnetEnable (Read/Write)
Table 197. Details of cfgSerialTelnetEnable
Description Enables or disables the Telnet console interface on CMC.
Legal Values
• 1 (TRUE)
• 0 (FALSE)
Default 0
cfgOobSnmp
This group contains parameters to congure the SNMP agent and trap capabilities of CMC. One instance of the group is allowed.
The CMC SNMP agent supports the standard RFC1213 mib-2, and the Dell enterprise-specic MIB.
Use this object with the cong or getcong subcommands.
To use this object property, you must have Chassis Conguration Administrator privilege.
NOTE
: You can congure any setting that is not preceded by the hash sign (#) in the output. To modify a congurable object,
use the -o option.
The following sections provide information about the objects in the cfgOobSnmp group.
132