Quick Reference Guide

144 RACADM Subcommand Details
testtrap
NOTE: To use this subcommand, you must have Test Alerts permission.
For iDRAC6 only, before you execute the testtrap subcommand, ensure that
the specified index in the RACADM cfgIpmiPet group is configured
properly. For more information, see "cfgIpmiPet" on page 241.
Table 2-48 provides a list and associated commands for the cfgIpmiPet group.
NOTE: The cfgIpmiPet group is applicable only for iDRAC6.
.
Synopsis
racadm testtrap -i <index>
Table 2-49 describes the testtrap subcommand options.
Subcommand Description
testtrap Tests the RAC’s SNMP trap alerting feature by sending a test trap
from iDRAC6 to a specified destination trap listener on the network.
Table 2-48. cfgIpmiPet Commands
Action Command
Enable the alert racadm config -g cfgIpmiPet -o
cfgIpmiPetAlertEnable -i 1 1
Set the destination
e-mail IP address
racadm config -g cfgIpmiPet -o
cfgIpmiPetAlertDestIpAddr -i 1
192.168.0.110
View the current test
trap settings
racadm getconfig -g cfgIpmiPet -i
<index>
where <index> is a number from 1 to 4
Table 2-49. testtrap Subcommand Options
Option Description
-i Specifies the index of the trap configuration to use for the test Valid
values are from 1 to 4.