Quick Reference Guide

RACADM Subcommand Details 119
Table 2-30 describes the serveraction power control options.
Output
The serveraction subcommand displays an error message if the requested
operation could not be performed, or a success message if the operation is
completed successfully.
setassettag
NOTE: To use this subcommand, you must have Administrator privilege.
Synopsis
racadm setassettag -m chassis <asset tag>
Table 2-30. serveraction Subcommand Options
String Description
<action> Specifies the action. The options for the <action> string are:
powerdown
— Powers down the managed system.
powerup
— Powers up the managed system.
powercycle
— Issues a power-cycle operation on the managed
system. This action is similar to pressing the power button on the
system’s front panel to power down and then power up the system.
powerstatus
— Displays the current power status of the server (ON
or OFF)
hardreset
— Performs a reset (reboot) operation on the managed
system.
Subcommand Description
setassettag Sets the N-byte ASCII asset tag for the chassis.