Owner's Manual

274 Using the CMC Directory Service
4
Click
Next
to run the Dell Schema Extender.
5
Click
Finish
.
The schema is extended. To verify the schema extension, use the
Microsoft Management Console (MMC) and the Active Directory
Schema Snap-In to verify that the following exist:
Classes — see Table 8-2 through Table 8-7
Attributes — see Table 8-8
See your Microsoft documentation for more information on how to enable
and use the Active Directory Schema Snap-In the MMC.
Table 8-2. Class Definitions for Classes Added to the Active Directory Schema
Class Name Assigned Object Identification Number (OID)
dellRacDevice 1.2.840.113556.1.8000.1280.1.1.1.1
dellAssociationObject 1.2.840.113556.1.8000.1280.1.1.1.2
dellRACPrivileges 1.2.840.113556.1.8000.1280.1.1.1.3
dellPrivileges 1.2.840.113556.1.8000.1280.1.1.1.4
dellProduct 1.2.840.113556.1.8000.1280.1.1.1.5
Table 8-3. dellRacDevice Class
OID 1.2.840.113556.1.8000.1280.1.1.1.1
Description Represents the Dell RAC device. The RAC device must be
configured as dellRacDevice in Active Directory. This configuration
enables CMC to send Lightweight Directory Access Protocol
(LDAP) queries to Active Directory.
Class Type Structural Class
SuperClasses dellProduct
Attributes dellSchemaVersion
dellRacType