Owner's Manual
226 Using the CMC Web Interface
5
For additional information, click
Help
.
Health OK Indicates that FlexAddress is present
and providing status to CMC. In the
event of a communication failure
between CMC and FlexAddress, CMC
cannot obtain or display health status
for FlexAddress.
Informational Displays information about FlexAddress
when no change in health status
(OK, Warning, Critical) has occurred.
Warning Indicates that only warning alerts have
been issued, and corrective action must
be taken. If corrective actions are not
taken, then critical failures that can
affect the integrity of the server could
occur.
Critical Indicates that at least one Failure alert
has been issued. Critical status
represents a system failure on the server,
and corrective action must be taken
immediately.
No Value When FlexAddress is absent, health
information is not provided.
iDRAC firmware Displays the iDRAC version currently installed on the server.
BIOS Version Displays the current BIOS version of the server module.
Slot Slot number of the server associated with the fabric location.
Location Displays the location of the Input/Output (I/O) module in the
chassis by group number (A, B, or C) and slot number (1 or 2).
Slot names: A1, A2, B1, B2, C1, or C2.
Fabric Displays the type of fabric.
Server-Assigned Displays the server-assigned WWN/MAC addresses that are
embedded in the controller's hardware.
Chassis-Assigned Displays the chassis-assigned WWN/MAC addresses that are
used for the particular slot.
Table 5-61. Status Page Information