218 Using the CMC Web Interface
To copy the QuickDeploy settings into the iDRAC Network Settings section,
click Auto-Populate Using QuickDeploy Settings. The QuickDeploy network
configurations settings are copied into the corresponding fields in the iDRAC
Network Configuration Settings table.
NOTE: Changes made to QuickDeploy fields are immediate, but changes made to
one or more iDRAC server network configuration settings may require a couple of
minutes to propagate from CMC to iDRAC. Pressing the Refresh button too soon
may display only partially correct data for one or more iDRAC servers.
iDRAC Network Settings
The iDRAC Network Settings section of the Deploy iDRAC page contains a
table listing all installed server’s iDRAC IPv4 and IPv6 network configuration
settings. Using this table you can configure the iDRAC network
configurations settings for each installed server. The initial values displayed
for each of the fields are the current values read from the iDRAC. Changing a
field and clicking Apply iDRAC Network Settings saves the changed field to
the iDRAC. To enable and set the iDRAC Network Settings:
1
Log in to the CMC Web interface.
2
Select
Server Overview
in the system tree.
3
Click the
Setup
tab.
The
Deploy iDRAC
page appears.
4
Select the check box for
QuickDeploy Enabled
to enable the
QuickDeploy settings.
5
Set the remaining
iDRAC Network Settings
accordingly.
Table 5-60. iDRAC Network Settings
Setting Description
Slot Displays the slot occupied by the server in the chassis.
Slot numbers are sequential IDs, from 1 to 16 (there are 16
slots available on the chassis), that help identify the
location of the server in the chassis.
NOTE: When there are fewer than 16 servers occupying
slots, only those slots populated by servers are displayed.