Users Guide

Table Of Contents
Conguring LED Blinking Using CMC Web Interface
To enable blinking for one, multiple, or all component LEDs:
In the left pane, go to any of the following pages:
Chassis Overview > Troubleshooting.
Chassis Overview > Chassis Controller > Troubleshooting.
Chassis Overview > Server Overview > Troubleshooting.
NOTE: Only servers can be selected on this page.
Chassis Overview > I/O Module Overview > Troubleshooting.
Storage > Troubleshooting > Identify.
NOTE: Physical disk per enclosures, virtual disks per enclosures, and external storage component LED can be selected on
this page.
To enable blinking of a component LED, select the Select/Deselect All option corresponding to the physical disk drive or virtual disk or
enclosures, and then click Blink. To disable blinking of a component LED, clear the Select/Deselect All option corresponding to the LED,
and then click Unblink.
Conguring LED Blinking Using RACADM
Open a serial/Telnet/SSH text console to CMC, log in, and type:
racadm setled -m <module> [-l <ledState>], where <module> species the module whose LED you want to congure.
Conguration options:
server-n where n = 1-4
switch-1
cmc-active
and <ledState> species whether or not the LED should blink. Conguration options:
0 — not blinking (default)
1 — blinking
racadm raid <operation> <component FQDD>, where the operation value is blink or unblink, and the FQDD is for the
component's physical disk drive, virtual disk and enclosures.
Conguring CMC Properties
You can congure CMC properties such as power budgeting, network settings, users, and SNMP and email alerts using the web interface
or RACADM commands.
Conguring iDRAC Launch Method Using CMC Web
Interface
To congure the iDRAC launch method from the General Chassis Settings page:
1 In the left pane, click Chassis Overview > Setup.
38
Installing and Setting Up CMC