Users Guide

Table Of Contents
Setting Chassis Physical Location and Chassis Name Using
Web Interface
To set the chassis location and chassis name using the CMC web interface:
1 In the left pane, go to Chassis Overview, and then click Setup .
2 On the General Chassis Settings page, type the location properties and the chassis name. For more information about setting chassis
properties, see the CMC Online Help.
NOTE: The Chassis Location eld is optional. It is recommended to use the Data Center, Aisle, Rack, and Rack Slot elds to
indicate the physical location of the chassis.
3 Click Apply. The settings are saved.
Setting Chassis Physical Location and Chassis Name Using
RACADM
To set the chassis name, location, date, and time by using the command line interface, see the setsysinfo and setchassisname commands.
For more information, see the Chassis Management Controller for PowerEdge VRTX RACADM Command Line Reference Guide.
Setting Date and Time on CMC
You can manually set the date and time, or you can synchronize the date and time with a Network Time Protocol (NTP) server.
Setting Date and Time on CMC Using CMC Web Interface
To set the date and time on CMC:
1 In the left pane, click Chassis Overview > Setup > Date/Time.
2 To synchronize the date and time with a Network Time Protocol (NTP) server, on the Date/Time page, select Enable NTP and
specify up to three NTP servers. To manually set the date and time, clear the Enable NTP option, and then edit the Date and Time
elds.
3 Select the Time Zone from the drop-down menu, and then click Apply.
Setting Date and Time on CMC Using RACADM
To set the date and time using the command line interface, see the cong command and cfgRemoteHosts database property group
sections in the Chassis Management Controller for PowerEdge VRTX RACADM Command Line Reference Guide available at dell.com/
support/manuals.
Conguring LEDs to Identify Components on the
Chassis
You can enable the LEDs of components (chassis, servers, physical disk drives, virtual disks, and I/O Modules) to blink so that you can
identify the component on the chassis.
NOTE
: To modify these settings, you must have the Chassis Conguration Administrator privilege.
Installing and Setting Up CMC 37