Users Guide

Table Of Contents
No feature card inserted.
What happens to FlexAddress feature if the server BIOS is updated from version 1.xx to version 2.xx?
The server module must be turned o before it can be used with FlexAddress. After the server BIOS update is complete, the server module
does not get chassis-assigned addresses until the server is power cycled.
How can an SD card be recovered if the SD card was not in the chassis when the deactivation command was run on the
FlexAddress?
The issue is that the SD card cannot be used to install FlexAddress on another chassis, if it was not in CMC when FlexAddress was
deactivated. To recover use of the card, insert the card back into a CMC in the chassis that it is bound to, reinstall FlexAddress, and then
deactivate the FlexAddress.
The SD card is properly installed and all the rmware or software updates are installed. The FlexAddress is active, the server
deployment screen does not display the options to deploy it? What is wrong?
This is a browser caching issue. Log o from the browser and relaunch.
What happens to FlexAddress if I need to reset my chassis conguration using the RACADM command, racresetcfg?
The FlexAddress feature will still be activated and ready to use. All fabrics and slots are selected as default.
NOTE: It is highly recommended that you turn o your chassis before running the RACADM command racresetcfg.
After disabling only the FlexAddressPlus feature (leaving FlexAddress still activated), why does the racadm setexaddr command on
the (stillactive) CMC fail?
If the CMC subsequently becomes active, with the FlexAddressPlus feature card still in the card slot, the FlexAddressPlus feature gets
reactivated, and slot or fabric exaddress conguration changes can resume.
IOM
After a conguration change, sometimes CMC displays the IP address as 0.0.0.0.
Click the Refresh icon to see if the IP address is set correctly on the switch. If an error is made in setting the IP/mask/gateway, the switch
does not set the IP address and returns a 0.0.0.0 in all elds.
Common errors are:
Setting the out-of-band IP address to be the same as, or on the same network as, the in-band management IP address.
Entering an invalid subnet mask.
Setting the default gateway to an address that is not on a network, which is directly connected to the switch.
Frequently Asked Questions
237