The Power Control page is displayed.
2 In the Operations column, from the drop-down menu, select one of the following power control operations for the required servers:
No Operation
Power On Server
Power O Server
Graceful Shutdown
Reset Server (warm boot)
Power Cycle Server (cold boot)
For information about the options, see the Online Help.
3 Click Apply.
A dialog box appears requesting for conrmation.
4 Click OK to perform the power management action (for example, reset the server).
Executing Power Control Operations on the IOM
You can remotely reset or turn on an IOM.
NOTE: To perform power management actions, you must have the Chassis Conguration Administrator privilege.
Executing Power Control Operations on IOM Using CMC Web
Interface
To execute power control operations on the I/O Module:
1 In the left pane, click Chassis Overview > I/O Module Overview > Power.
2 On the Power Control page, for the IOM, from the drop-down menu, select the operation you want to execute (power cycle).
3 Click Apply.
Executing Power Control Operations on the IOM Using
RACADM
To execute power control operations on the IOM using RACADM, open a serial/Telnet/SSH text console to CMC, log in, and type:
racadm chassisaction -m switch <action>
where <action> indicates the operation you want to execute: power cycle.