Users Guide

Table Of Contents
NOTE: To apply chassis events conguration changes, you must have the Alert Conguration privilege.
1 In the left pane, click Chassis Overview > Alerts.
2 On the Chassis Events page, under the Alerts Filter section, select one or more of the following categories:
System Health
Storage
Conguration
Audit
Updates
3 Select one or more of the following severity levels:
Critical
Warning
Informational
The Monitored Alerts section displays the results based on the selected category and severity. For information about the eld
descriptions on the this page, see the Online Help.
4 Click Apply.
Setting Event Alerts Using RACADM
To set an event alert, run the eventfilters command. For more information, see the Chassis Management Controller for PowerEdge
VRTX RACADM Command Line Reference Guide available at dell.com/support//manuals.
Conguring Alert Destinations
The management station uses Simple Network Management Protocol (SNMP) to receive data from CMC.
You can congure the IPv4 and IPv6 alert destinations, email settings, and SMTP server settings, and test these settings.
Before conguring the email alert or SNMP trap settings, make sure that you have the Chassis Conguration Administrator privilege.
Conguring SNMP Trap Alert Destinations
You can congure the IPv6 or IPv4 addresses to receive the SNMP traps.
Conguring SNMP Trap Alert Destinations Using CMC Web Interface
To congure IPv4 or IPv6 alert destination settings using CMC Web interface:
1 In the left pane, click Chassis Overview > Alerts > Trap Settings.
2 On the Chassis Event Alert Destinations page, type the following:
In the Destination eld, type a valid IP address. Use the quad-dotted IPv4 format, standard IPv6 address notation, or FQDN. For
example: 123.123.123.123 or 2001:db8:85a3::8a2e:370:7334 or dell.com.
Choose a format that is consistent with the networking technology or infrastructure. The Test Trap functionality cannot detect
incorrect choices based on the current network conguration (example, use of an IPv6 destination in an IPv4-only environment).
In the Community String eld, enter a valid community name to which the destination management station belongs.
This community string diers from the community string on the Chassis Overview > Network > Services page. The SNMP traps
community string is the community that CMC uses for outbound traps destined to management stations. The community string
Conguring
CMC To Send Alerts 123